02-0001 - Error message "No parent component with own counter found."
#
Problem
During the creation of a maintenance report you get the following error message while saving the report: Internal error [MainCompCounterLookup]: No parent component with own counter found.
#
Reason
While saving a maintenance report the system also updates the running hour counters of affected components. The counter value given in the report will be set for all sub-components without an independent counter. If the component you are creating the report for doesn't have an own counter, the system tries to find a parent component with an own counter - beginning from this component the counter update will be done for all sub-components.
If such a parent component with an independent counter cannot be found, the counter update of the related parent and sub-components cannot be performed. Only the component you are creating report for and their sub-components will be updated.
#
Solution
Usually you'll have to find a parent component in the hierarchy that has an independent running hours counter. Find this component and use the Edit function for setting the checkbox Uses own counter.